June 11, 2022 |
SCD 14
SCD 14
Flow Up 100 m3/min.
NORMAL WORKING PROCEDURE
- Condensate is passed through inlet into container.
- Condensate will fill container chamber.
- Once condensate set limit has been reached, measured by level sensor, condensate valve will open allowing condensate to pass through strainer and escape through outlet.
- When minimum condensate level is reached in container the level sensor will shut the condensate valve for cycle to repeat.
SPECIFICATIONS
- Maximum compressor capacity: 100m3/min.
- Min./max. system pressure: 0 bar / 16 bar
- Valve type: 2/2 way, direct acting
- Valve oriface: 4.0 mm
- Valve seals: FPM
- Inlet connection: 1/2” (BSP or NPT)
- Outlet connection: 1/4” (BSP or NPT)
- Inlet height: 11cm(top) & 1.5 & 7.5cm(side)
- Supply voltage options:230 VAC / 115 VAC, 24 VAC / 24 VDC
- Serviceable valve: YES
- TEST feature: YES
- Environmental protection: IP65 (NEMA4)
- Integrated mesh strainer: YES
- Alarm contact options: Alarm normally closed (NC), Alarm normally open (NO)